Fire Barriers

During a major fire large compartment, walls or enclosures may be subjected to extreme conditions and impact damage due to falling debris, leading to failure and in some cases total collapse.

In circumstances of extreme fire it is vital both materials and construction are capable of sustaining their design function. When subjected to these extreme conditions, Invicta Durasteel achieved a fire rating of 240 minutes and together with its ability to withstand impact gives it the strength to protect in the harshes of fires. This was clearly illustrated when fire broke out at the Bass Charrington Runcorn Brewery. It rapidly spread through the roof insulation devastating everything in it's path. A durasteel barrier stopped the fire from spreading tio the bottling plant, saving buildings, equipment and plant valued at £10 million and anabling production to continue on a limited scale.The Durasteel barrier acted as an external wall during the re-construction of the fire damaged site, withstanding all the elements.

Durasteel Fire Barrier Features:

  • Four Hour Fire Resistant
  • Impact Resistant
  • Moisture Resistant
  • Lightweight - No foundations required
  • Space-Saving, with excellent Structural Strength & Integrity
  • Demountable / Remountable
  • Maintenance Free
  • Suitable for Internal and External Locations
  • Can be Prefabricated - offsite
  • Purpose Built to meet Individual Requirements
  • Vibration Resistance

Typical barrier construction: Durasteel partitions provide vertical fire barriers to meet the requirements of BS 476: Part 22: 1987. Durasteel partition and barrier systems combine superior levels of fire resistance and high surface impact resistance. They will withstand the wear and tear of industrial and commercial environments and resist the forces of high pressure hose streams encountered during fire-fighting. These outstanding characteristics provide a durable and fire safe method for the construction of vertical barrier systems to maintain compartmentation in industrial environments. When designing the Durasteel framing system, consideration must be made for expansion, deflection, windloading and loadbearing requirements. The constructions have been tested to both fire and impact resistance in accordance with BS 476: Part 22: 1987 and similar international standards with the construction subjected to impact of 3000Nm both prior and after the fire test.

Heathrow Airport Terminal 5
Heathrow Airport Terminal 5
London, England
Petronas Twin Towers
Petronas Twin Towers
Kuala Lumpur, Malaysia